NEUROCOM 16 / 19 EEG

NEUROCOM — 16 / 19-channel electroencephalograph

Digital EEG in NEUROCOM 16 and NEUROCOM 19 configurations: routine recording, functional tests and evoked potentials.

NEUROCOM 16
NEUROCOM 16

Digital 16-channel EEG

  • Routine EEG
  • Hyperventilation
  • Photic stimulation
  • IFCN protocol
  • Auditory and visual EP
  • EEG caps via a separate connector
Request a quote
NEUROCOM 19
NEUROCOM 19

Digital 19-channel EEG

  • Routine EEG
  • Hyperventilation
  • Photic stimulation
  • IFCN protocol
  • Auditory and visual EP
  • EEG caps via a separate connector
  • Standard 10–20 system
  • 4 HF channels
  • ECG channel
Request a quote

Key specifications

Sampling rate
4000 / 500 Hz
EEG range
1–12,000 µV
Resolution
24 bit
Bandwidth
0.5–50 Hz
Internal noise
< 1 µV
Input impedance
diff. > 10 MΩ · common-mode > 100 MΩ
CMRR
>120 dB
Interface
USB
Routine EEG mode
IFCN: continuous recording, test markers
Photic stimulation (IPS)
1–30 Hz, 13 frequencies in the IFCN protocol
Additional channels (NEUROCOM 19)
EMG + ECG in sync with EEG
Video (Pro · NEUROCOM 19)
Recorded in sync with EEG and markers

Public procurement codes (Prozorro)

Ready-to-use wording for Ukrainian tender documents, specifications and contracts. We can send technical requirements on request.

Комплекс електроенцефалографічний комп'ютерний

ДК 021:2015
33120000-7 Системи реєстрації медичної інформації та дослідне обладнання
НК 024:2023
11467 Електроенцефалограф
НК 031:2024
Z12100302 Електроенцефалографи

Five advantages of the IFCN mode

  • Continuous EEG recording per the IFCN protocol The whole study is one gap-free file; tests (eyes open / closed, photic stimulation) are flagged with event markers while recording.
  • Protocol-driven photic stimulation Rhythmic photic stimulation at 1–30 Hz: 13 frequencies of 5 s each, triggered at the right moment of the recording; stimulus-locked artifacts are removed.
  • Additional EMG channels Myogram recorded in sync with the EEG — easily tell muscle artifacts apart and assess muscle activity (NEUROCOM 19).
  • ECG channel on the trace ECG on the same time axis as the EEG helps tell cardiac artifacts apart and monitor rhythm during recording (NEUROCOM 19).
  • Synchronized video monitoring Patient video is recorded with the EEG and event markers — behaviour during episodes is visible next to the trace; the file can be deleted after review (Pro · NEUROCOM 19).

Software capabilities

Software NEUROCOM

  • Patient file: multiple databases on one or several media; network use (record and review on different PCs); search, sort, statistics; shared base with REO / SPIRO; study import / export
  • Study-type and test-protocol editor: number of tests, lead schemes, stimulation, sensitivity / speed, duration, report template and norm table
  • Montage and lead-scheme editor (built-in and user); spatial filtering of EEG leads
  • IFCN mode (European protocol): continuous EEG recording in one file, tests flagged with event markers; rhythmic photic stimulation at 1–30 Hz per the protocol; additional EMG and ECG channels and synchronized video (NEUROCOM 19 / Pro)
  • Protocol EEG recording: resting, activation reaction, rhythmic photostimulation, hyperventilation; automatic test advance; event markers
  • Filtering of all or selected leads (LP / HP / band-pass, custom cut-offs and order); zero-phase symmetric filters; adaptive mains comb
  • ICA / BSS (Independent Component Analysis / Blind Source Separation): blind source separation; ICA-component extraction
  • Artifact rejection without shortening the record (electrode and physiological) by subtracting artifact components; for EP — removal of stimulus-locked artifacts
  • EEG-phenomenon markup by class with amplitude, duration, period and localization; automatic rhythm parameters and auto description with report editor
  • Spectral analysis of EEG / EP / ICA (resolution and window choice); correlation and coherence analysis
  • Topographic mapping of EEG, EP and ICA: power, frequency, potential, dipole and symmetry maps; map families; driven-rhythm maps and harmonics
  • Spatial localization of individual phenomena / components; 3D tomography; comparison with the patient’s MRI
  • Flash VEP; separate odd/even stimulus averaging; accumulation-quality control; EP re-averaging with ICA
  • Integration with medical information systems (HIS / MIS)
  • Our own solution for telemedicine consultations, storage and data exchange — CLORM
  • Interface, reports and printouts in Ukrainian, English and Russian

Pro software — NEUROCOM 19 only

  • Patient video monitoring: image recorded in sync with EEG and event markers for later behaviour review; the file can be deleted after processing
  • Checkerboard and arbitrary on-display image stimulation; fibre-optic sync with a second monitor
  • Long-latency auditory EP (DSVP), cognitive P300, short-latency BAEP; separate averaging and quality control
  • Biofeedback: real-time training on amplitudes of selected EEG rhythms
  • Brain-death confirmation under a dedicated study protocol

Request a quote

Documents and guides

Quick guides

Minimizing skin–electrode impedance

ECG · EEG · Holter · rheography · quick guide

≤ 5 kΩEEG: impedance of each electrode (check in the software)
5 stepsskin preparation before applying electrodes
1 usedisposable electrode: never reuse
No prepartifacts, baseline drift, mains noise

1Why impedance must be low

No preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z high After preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z low

Most of the impedance comes from the stratum corneum (dead cells, oil, dust). The higher it is, the more mains noise and baseline drift, especially on microvolt-level signals (EEG).

2Skin preparation: 5 steps

  1. 1Siteaway from muscle, folds, scars and wounds
  2. 2Hairshave or part it
  3. 3Cleanalcohol, let it dry completely
  4. 4Abraderub lightly until slightly pink
  5. 5Electrodefresh, with gel (RVG: moistened); press firmly, check impedance

3By examination type

ECG

  • Ag/AgCl electrodes, not dried out, within expiry date
  • Cable without strain; patient relaxed and not talking

EEG

  • Each electrode ≤ 5 kΩ and roughly equal
  • Part the hair, gel/paste, cap fitted snugly
  • Check impedances in the software before recording

Holter

  • Shave, always degrease and lightly abrade the skin
  • Secure with tape, leave a cable loop (strain relief)
  • For long recordings replace electrodes per manufacturer’s guidance

Rheography (REG, RVG)

  • REG: gel electrodes over the whole contact area
  • RVG: moisten the electrode/pad, do not let it dry out
  • Firm fixing (strap/tape), no folds or air

✔ Pre-recording checklist

Skin cleaned and fully dry
Hair removed
Electrodes fresh, with gel (RVG: moistened), in date
Firm contact, no folds or air
Impedance checked in software (EEG ≤ 5 kΩ)
Cables without strain, away from mains cords
Do not “fix” high impedance with gain or filters — re-apply the electrode.Never reuse disposable electrodes, mix new and old ones, or apply to irritated or damaged skin.

Electrode contact · guide · PDF 262 KB

General earthing requirements for functional diagnostics systems

Earthing of functional diagnostics devices

Standards: IEC 60601-1, IEC 62353, local wiring rules

≤ 2 Ωworking earth (FE) loop resistance
≤ 0.1 Ωcontact resistance: device clamp — bar
≥ 15 mfrom other earth electrodes (lightning protection, lift)
TN-S / ITTN-C (PEN) prohibited

1Mains: TN-S or IT only

✔ TN-S (correct) L N PE PC PE and N are separate ✖ TN-C (prohibited) L PEN PC PE merged with N — noise!

The protective conductor is the third (earth) pin of the socket. Never fit a PE→N jumper in the room. IT — via a medical isolating transformer.

2“Star” layout, not “daisy chain”

✔ Star BAR PCShield* * if present ✖ Daisy chain bar PCShield* in series → ground loops

Each device goes to the bar with its own conductor. Loops pick up mains noise into the microvolt-level signal.

3Equipotential bonding in the room

EQUIPOTENTIAL BONDING BAR Device PCRoom shield* * if present to the separate FE loop ≤ 2 Ω Braided copper strap between earthing points fewer artifacts in the record Contact ≤ 0.1 Ω clamp → bar: tighten, clean, no paint/oxide

4Earthing loop requirements

  • A separate working (functional) earth, FE, independent of the hospital protective earth (protective earth norm: up to 4 Ω).
  • Distance to other earthing systems — at least 15 m.
  • Connect only through the third (earth) conductor of the socket.

5Testing and operation

  • Measure contact resistances and insulation before first use.
  • Then periodically per clinic policy (usually once a year).
  • Record the results in a log.

✔ Pre-start checklist

Mains is TN-S or IT, no PEN in the room
Device PC chassis — on the bar
Room shield (if present) — on the bar
“Star” connection, no daisy chains
FE loop ≤ 2 Ω (measured)
Clamp contact resistances ≤ 0.1 Ω
Do not switch the device on if the earthing has not been measured or the socket has no earth conductor.Prohibited: PEN conductor, PE→N jumper in the socket, daisy-chained connection of devices.

Earthing · guide · PDF 93 KB

Frequently asked questions

What is NEUROCOM for?

NEUROCOM is a digital EEG system in NEUROCOM 16 and NEUROCOM 19 configurations for neurology, epileptology and neurophysiology labs. Clinically it is used for routine EEG, functional tests (hyperventilation, photic stimulation and others), auditory and visual evoked potentials, short-latency EPs, activity mapping, biofeedback and patient video monitoring (EEG-synced video saved for later review). The system supports analysis and documentation of the study, with optional exchange via the facility HIS.

Does it integrate with HIS?

Yes. Results go to the facility’s medical information systems (HIS / MIS). Separately, our own solution for telemedicine consultations, storage and data exchange — CLORM — is available.

Price, quote, warranty and service: what is included and how to order?

The public price list is in Resources, PDF: price list.

For a quote, use “Request a quote” or message Telegram / Viber / WhatsApp +38 095 047-4000. The same applies to a custom configuration.

The price includes delivery, commissioning and staff training.

24-month warranty, with service support throughout the entire operating life of the equipment.

Call Get a quote