Holter ECG and combined ECG+BP system

CARDIOSENS — Holter ECG and combined ECG+BP

Two options: a digital 3-channel Holter ECG and a separate combined ECG+BP system. A 4G telemetry option is available.

CARDIOSENS K (ECG)
CARDIOSENS K (ECG)

Digital 3-channel Holter ECG

  • 24–72 hours of ECG
  • Miniature size, 60 g
  • Only 4 wires for 3 leads
  • Built-in battery and built-in 32 GB memory
Request a quote
CARDIOSENS BP (ECG+BP)
CARDIOSENS BP (ECG+BP)

Combined ECG + BP system

  • 24–72 hours of ECG
  • 24 hours of BP readings
  • Miniature size, up to 200 g
  • Only 4 wires for 3 leads
  • Built-in battery and built-in 32 GB memory
Request a quote

Key specifications

ECG recording
24–72 hours, 3 channels
Input signal range
± 8 mV
Bandwidth
0.5–75 Hz
CMRR
110 dB
Internal noise
< 5 µV
Weight
≈ 60 g (ECG) · ≈ 200 g (ECG+BP)
BP (BP version)
up to ~250 readings; adult and pediatric modes
BP range
10–280 mmHg (adults) · 5–155 mmHg (children)
Memory
built-in, 32 GB
Interfaces
USB-C, Bluetooth

Public procurement codes (Prozorro)

Ready-to-use wording for Ukrainian tender documents, specifications and contracts. We can send technical requirements on request.

Комплекс моніторингу електрокардіосигналів (амбулаторний реєстратор за методом Холтера)

ДК 021:2015
33120000-7 Системи реєстрації медичної інформації та дослідне обладнання
НК 024:2023
35162 Реєстратор амбулаторний для тривалого електрокардіографічного моніторингу
НК 031:2024
Z12050402 Реєстратори ЕКГ за холтером
Комплекс комбінованого амбулаторного моніторингу електрокардіосигналів та артеріального тиску з функцією автоматичного вимірювання артеріального тиску

ДК 021:2015
33120000-7 Системи реєстрації медичної інформації та дослідне обладнання
НК 024:2023
35162 Реєстратор амбулаторний для тривалого електрокардіографічного моніторингу
НК 031:2024
Z12050402 Реєстратори ЕКГ за холтером

Software capabilities

Software CARDIOSENS

  • Patient file: multiple databases and folders, monitoring diary, network use
  • Recorder programming and control ECG (USB-C / Bluetooth), record download to PC over USB
  • Artifact filtering, QRS detection and markup
  • Morphological classification (normal, SVE, VE, aberrant, unclassified, artifacts; with a pacemaker — spontaneous / paced / fusion), classifier training and manual cluster editing
  • P waves, P–Q intervals, atrial activity; scatterplot; electronic magnifier
  • Automatic rhythm and conduction analysis: counts per 24 h, hour, day and night; episode descriptions; dictionary and manual edits
  • Rhythm: tachycardia, bradycardia, pauses; atrial and ventricular fibrillation / flutter
  • SVE and VE: single, interpolated, couplets, polymorphic, bi-/tri-/quadrigeminy, runs; SVT and VT; R-on-T
  • Conduction disorders and AV block; high-grade ectopy (Lown 4b, 5); automatic pacemaker-pulse detection
  • ST-T with decision-rule and episode-boundary correction; QRS morphology; Q–T intervals
  • Heart rate variability (HRV) in time and frequency domains (ESC working-group norms, PARS — regulatory systems activity index); AC/DC via PRSA; heart-rate turbulence (HRT)
  • EASI-12 reconstruction of 12 leads from the 3-channel recording
  • Auto report with ECG strips, conclusion-form editor, print
  • Export of records and tables (network, e-mail, Excel, MATLAB)
  • HIS integration
  • Integration with our own shared-access and data-storage system CLORM
  • Interface, reports and printouts in Ukrainian, English and Russian

ECG+BP version

  • BP per NBREP: SBP / DBP / mean / pulse pressure and HR trends; cuff oscillation and pulse-wave review
  • Distribution histograms, diagrams, correlation, cosinor analysis
  • Pressure-load indices (measurement, time, area); BP variability (VAR1–3)
  • Nocturnal dip (SNS), day / night / custom intervals; morning-surge magnitude and rate
  • Calibration BP readings and offsets; adult and pediatric protocols
  • Summary tables and a separate BP report (form editor, fragment and full-report print)

Request a quote

Documents and guides

Quick guides

Minimizing skin–electrode impedance

ECG · EEG · Holter · rheography · quick guide

≤ 5 kΩEEG: impedance of each electrode (check in the software)
5 stepsskin preparation before applying electrodes
1 usedisposable electrode: never reuse
No prepartifacts, baseline drift, mains noise

1Why impedance must be low

No preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z high After preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z low

Most of the impedance comes from the stratum corneum (dead cells, oil, dust). The higher it is, the more mains noise and baseline drift, especially on microvolt-level signals (EEG).

2Skin preparation: 5 steps

  1. 1Siteaway from muscle, folds, scars and wounds
  2. 2Hairshave or part it
  3. 3Cleanalcohol, let it dry completely
  4. 4Abraderub lightly until slightly pink
  5. 5Electrodefresh, with gel (RVG: moistened); press firmly, check impedance

3By examination type

ECG

  • Ag/AgCl electrodes, not dried out, within expiry date
  • Cable without strain; patient relaxed and not talking

EEG

  • Each electrode ≤ 5 kΩ and roughly equal
  • Part the hair, gel/paste, cap fitted snugly
  • Check impedances in the software before recording

Holter

  • Shave, always degrease and lightly abrade the skin
  • Secure with tape, leave a cable loop (strain relief)
  • For long recordings replace electrodes per manufacturer’s guidance

Rheography (REG, RVG)

  • REG: gel electrodes over the whole contact area
  • RVG: moisten the electrode/pad, do not let it dry out
  • Firm fixing (strap/tape), no folds or air

✔ Pre-recording checklist

Skin cleaned and fully dry
Hair removed
Electrodes fresh, with gel (RVG: moistened), in date
Firm contact, no folds or air
Impedance checked in software (EEG ≤ 5 kΩ)
Cables without strain, away from mains cords
Do not “fix” high impedance with gain or filters — re-apply the electrode.Never reuse disposable electrodes, mix new and old ones, or apply to irritated or damaged skin.

Electrode contact · guide · PDF 262 KB

CARDIOSENS: electrodes and recording start

Holter ECG · ECG + BP · quick guide

Only 4electrodes, no separate ground: faster to apply, fewer cables
24–72 hcontinuous recording, no recharging
up to ~250BP measurements per recording (BP version)
Keep dryrecorder and electrodes: no shower or bath

1Electrode placement: 4 electrodes

−V1V4V5 RL
  • White — left subclavicular area (−)
  • Red — right, 4th intercostal space, position V1 (1+)
  • Yellow — position V4 (2+)
  • Green — position V5 (3+)

The recorded signals roughly match the leads: 3 channels: 1 — V1, 2 — aVF, 3 — V5 (EASI-12 optional).

2Recorder and lead cable

Recorder and lead cable
  • Recorder: in a pouch on the belt or on a shoulder strap, not in a pocket
  • Leave a cable loop at each electrode (strain relief) and tape the cable down
  • Keep cables slack: big loops, no strain or twisting
  • No synthetic vests or T-shirts (static); prefer natural fabrics

3Starting a recording: 5 steps

  1. 1Patientselect or create a record in the database
  2. 2Recorder“Recorder preparation”: mode, scheme, time; write
  3. 3Electrodesprepare the skin, apply per the scheme, connect the cable
  4. 4Control ECG3 clean channels; otherwise re-apply the electrode
  5. 5Startstart monitoring, note the time, hand over the diary

4BP version: the cuff

  • Cuff size by upper-arm circumference; adult / child protocol; control reading and correction in the software
  • Place on the upper arm, lower edge 2–3 cm above the elbow crease; snug, one finger fits under it
  • Cuff on the left arm; run the tube across the chest, behind the neck and down the shoulder to the cuff — slack, no strain
  • During a measurement: arm relaxed and still, at heart level

5What to tell the patient

  • With pain, breathlessness or palpitations press the patient button on the recorder
  • Keep a diary: sleep, meals, activity, medication, symptoms — with exact times
  • Do not remove or wet it; no electric blankets
  • If an electrode comes off, press it back or replace it and note the time in the diary

✔ Checklist before the patient leaves

Skin prepared, electrodes fresh, colours per scheme
Cable loops in place, no strain, recorder secured
Control ECG: 3 clean channels
BP: cuff size right, control reading taken
Patient knows the button, diary and removal time
Start time noted
Do not start a recording without a control ECG — noise that gets into a 24 h recording cannot be fixed later.Do not apply electrodes to irritated skin; do not place the cuff on an arm with a catheter or fistula.

CARDIOSENS · placement and start · PDF 850 KB

General earthing requirements for functional diagnostics systems

Earthing of functional diagnostics devices

Standards: IEC 60601-1, IEC 62353, local wiring rules

≤ 2 Ωworking earth (FE) loop resistance
≤ 0.1 Ωcontact resistance: device clamp — bar
≥ 15 mfrom other earth electrodes (lightning protection, lift)
TN-S / ITTN-C (PEN) prohibited

1Mains: TN-S or IT only

✔ TN-S (correct) L N PE PC PE and N are separate ✖ TN-C (prohibited) L PEN PC PE merged with N — noise!

The protective conductor is the third (earth) pin of the socket. Never fit a PE→N jumper in the room. IT — via a medical isolating transformer.

2“Star” layout, not “daisy chain”

✔ Star BAR PCShield* * if present ✖ Daisy chain bar PCShield* in series → ground loops

Each device goes to the bar with its own conductor. Loops pick up mains noise into the microvolt-level signal.

3Equipotential bonding in the room

EQUIPOTENTIAL BONDING BAR Device PCRoom shield* * if present to the separate FE loop ≤ 2 Ω Braided copper strap between earthing points fewer artifacts in the record Contact ≤ 0.1 Ω clamp → bar: tighten, clean, no paint/oxide

4Earthing loop requirements

  • A separate working (functional) earth, FE, independent of the hospital protective earth (protective earth norm: up to 4 Ω).
  • Distance to other earthing systems — at least 15 m.
  • Connect only through the third (earth) conductor of the socket.

5Testing and operation

  • Measure contact resistances and insulation before first use.
  • Then periodically per clinic policy (usually once a year).
  • Record the results in a log.

✔ Pre-start checklist

Mains is TN-S or IT, no PEN in the room
Device PC chassis — on the bar
Room shield (if present) — on the bar
“Star” connection, no daisy chains
FE loop ≤ 2 Ω (measured)
Clamp contact resistances ≤ 0.1 Ω
Do not switch the device on if the earthing has not been measured or the socket has no earth conductor.Prohibited: PEN conductor, PE→N jumper in the socket, daisy-chained connection of devices.

Earthing · guide · PDF 93 KB

Frequently asked questions

What is CARDIOSENS for?

CARDIOSENS is a Holter monitor for ambulatory and inpatient long-term ECG recording (typically 24–72 hours) and, in the combined configuration, concurrent blood-pressure monitoring. Clinically it is used to detect rhythm and conduction disorders outside the consulting room (tachy-/bradycardia, pauses, SVE/VE, atrial fibrillation / flutter, AV block, etc.), assess 24-hour ECG and BP dynamics (including NBREP-style BP analysis), support therapy follow-up and select patients for further work-up. A telemetry option can transmit data; analysis runs in the system software with facility HIS integration.

Does it integrate with HIS?

Yes. Results go to the facility’s medical information systems (HIS / MIS). Separately, our own solution for telemedicine consultations, storage and data exchange — CLORM — is available.

Price, quote, warranty and service: what is included and how to order?

The public price list is in Resources, PDF: price list.

For a quote, use “Request a quote” or message Telegram / Viber / WhatsApp +38 095 047-4000. The same applies to a custom configuration.

The price includes delivery, commissioning and staff training.

24-month warranty, with service support throughout the entire operating life of the equipment.

Call Get a quote