Digital 12-channel ECG

CARDIOLAB — 12-channel electrocardiograph

A computer electrocardiograph for clinics, hospitals and sports medicine. Integrates with the facility HIS.

Electrocardiograph CARDIOLAB

Digital 12-channel ECG

  • Resting ECG with auto-interpretation
  • Vector ECG analysis
  • Heart rate variability (HRV) and ANS assessment (Baevsky / PARS — regulatory systems activity index)
  • Cycle ergometry and treadmill tests
  • Phonocardiography
  • Athlete assessment after Dushanin
Request a quote

Key specifications

Recording range
± 330 mV
Frequency range
0.05–200 Hz
Resolution
24 bit
Internal noise
< 5 µV
Interfaces
USB, Bluetooth
Other
Pacemaker detection

Public procurement codes (Prozorro)

Ready-to-use wording for Ukrainian tender documents, specifications and contracts. We can send technical requirements on request.

Комплекс електрокардіографічний комп'ютерний багатоканальний

ДК 021:2015
33120000-7 Системи реєстрації медичної інформації та дослідне обладнання
НК 024:2023
16231 Професійний багатоканальний електрокардіограф
НК 031:2024
Z12050302 Електрокардіографи розширеної діагностики

Software capabilities

Software CARDIOLAB

  • Patient file: archives, folders, cards, search, statistics
  • Standard ECG recording (10 s – 2 min) in 12 standard leads and in Frank, Neb, Slopak and other lead systems
  • Automatic PQRST markup, parameter table, manual marker correction
  • Automatic syndromic interpretation; conclusion editor and custom forms
  • ST and QT analysis
  • Vector ECG: F / Sl / H projections and 3D; Frank leads or transform from 12 leads
  • ECG recording and analysis for patients with an implanted pacemaker
  • HRV: time-domain, spectral and geometric analysis (ESC WG 1996 and Baevsky)
  • Autonomic tone assessment and composite PARS score
  • ANS tests: orthostatic, deep breathing, Valsalva, exercise; automatic ANS conclusion
  • Phonocardiography: heart sounds and murmurs, electrical / mechanical systole; time–frequency analysis; Maas–Weber band playback; sound library
  • Ergometry: standard and user protocols (cycle / treadmill); load control
  • During exercise: averaged QRS, ST level and slope, HR, alarm parameters
  • PWC 150 / 170; HR, ST, ∠ST plots; Vo₂ / Vo₂max / DP; ST hysteresis; SThist, ST/HR; dQT, dPQ, dQRS
  • HRV analysis on monitor segments recorded during exercise
  • Athlete express assessment after Dushanin; individual card; team review
  • Print strips and reports on laser / inkjet printers
  • Export (Word, Excel, Matlab, raw records); e-mail
  • Integration with medical information systems (HIS / MIS)
  • Our own solution for telemedicine consultations, storage and data exchange — CLORM
  • Interface, reports and printouts in Ukrainian, English and Russian

Request a quote

Documents and guides

Quick guides

Minimizing skin–electrode impedance

ECG · EEG · Holter · rheography · quick guide

≤ 5 kΩEEG: impedance of each electrode (check in the software)
5 stepsskin preparation before applying electrodes
1 usedisposable electrode: never reuse
No prepartifacts, baseline drift, mains noise

1Why impedance must be low

No preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z high After preparation ElectrodeGelStratum corneumEpidermisDermisFatRgelRscRsub Z low

Most of the impedance comes from the stratum corneum (dead cells, oil, dust). The higher it is, the more mains noise and baseline drift, especially on microvolt-level signals (EEG).

2Skin preparation: 5 steps

  1. 1Siteaway from muscle, folds, scars and wounds
  2. 2Hairshave or part it
  3. 3Cleanalcohol, let it dry completely
  4. 4Abraderub lightly until slightly pink
  5. 5Electrodefresh, with gel (RVG: moistened); press firmly, check impedance

3By examination type

ECG

  • Ag/AgCl electrodes, not dried out, within expiry date
  • Cable without strain; patient relaxed and not talking

EEG

  • Each electrode ≤ 5 kΩ and roughly equal
  • Part the hair, gel/paste, cap fitted snugly
  • Check impedances in the software before recording

Holter

  • Shave, always degrease and lightly abrade the skin
  • Secure with tape, leave a cable loop (strain relief)
  • For long recordings replace electrodes per manufacturer’s guidance

Rheography (REG, RVG)

  • REG: gel electrodes over the whole contact area
  • RVG: moisten the electrode/pad, do not let it dry out
  • Firm fixing (strap/tape), no folds or air

✔ Pre-recording checklist

Skin cleaned and fully dry
Hair removed
Electrodes fresh, with gel (RVG: moistened), in date
Firm contact, no folds or air
Impedance checked in software (EEG ≤ 5 kΩ)
Cables without strain, away from mains cords
Do not “fix” high impedance with gain or filters — re-apply the electrode.Never reuse disposable electrodes, mix new and old ones, or apply to irritated or damaged skin.

Electrode contact · guide · PDF 262 KB

General earthing requirements for functional diagnostics systems

Earthing of functional diagnostics devices

Standards: IEC 60601-1, IEC 62353, local wiring rules

≤ 2 Ωworking earth (FE) loop resistance
≤ 0.1 Ωcontact resistance: device clamp — bar
≥ 15 mfrom other earth electrodes (lightning protection, lift)
TN-S / ITTN-C (PEN) prohibited

1Mains: TN-S or IT only

✔ TN-S (correct) L N PE PC PE and N are separate ✖ TN-C (prohibited) L PEN PC PE merged with N — noise!

The protective conductor is the third (earth) pin of the socket. Never fit a PE→N jumper in the room. IT — via a medical isolating transformer.

2“Star” layout, not “daisy chain”

✔ Star BAR PCShield* * if present ✖ Daisy chain bar PCShield* in series → ground loops

Each device goes to the bar with its own conductor. Loops pick up mains noise into the microvolt-level signal.

3Equipotential bonding in the room

EQUIPOTENTIAL BONDING BAR Device PCRoom shield* * if present to the separate FE loop ≤ 2 Ω Braided copper strap between earthing points fewer artifacts in the record Contact ≤ 0.1 Ω clamp → bar: tighten, clean, no paint/oxide

4Earthing loop requirements

  • A separate working (functional) earth, FE, independent of the hospital protective earth (protective earth norm: up to 4 Ω).
  • Distance to other earthing systems — at least 15 m.
  • Connect only through the third (earth) conductor of the socket.

5Testing and operation

  • Measure contact resistances and insulation before first use.
  • Then periodically per clinic policy (usually once a year).
  • Record the results in a log.

✔ Pre-start checklist

Mains is TN-S or IT, no PEN in the room
Device PC chassis — on the bar
Room shield (if present) — on the bar
“Star” connection, no daisy chains
FE loop ≤ 2 Ω (measured)
Clamp contact resistances ≤ 0.1 Ω
Do not switch the device on if the earthing has not been measured or the socket has no earth conductor.Prohibited: PEN conductor, PE→N jumper in the socket, daisy-chained connection of devices.

Earthing · guide · PDF 93 KB

Frequently asked questions

What is CARDIOLAB for?

CARDIOLAB is a computer 12-channel ECG system for functional diagnostics rooms, cardiology, hospitals and sports medicine. Clinically it is used for resting ECG with automatic analysis and reporting, autonomic assessment via HRV and functional tests (including Baevsky / PARS), exercise testing on a cycle ergometer or treadmill (ST/HR control, PWC), phonocardiography and rapid athlete fitness assessment. Results are stored in the patient archive and can be sent to the facility’s hospital information system (HIS).

Does it integrate with HIS?

Yes. Results go to the facility’s medical information systems (HIS / MIS). Separately, our own solution for telemedicine consultations, storage and data exchange — CLORM — is available.

Price, quote, warranty and service: what is included and how to order?

The public price list is in Resources, PDF: price list.

For a quote, use “Request a quote” or message Telegram / Viber / WhatsApp +38 095 047-4000. The same applies to a custom configuration.

The price includes delivery, commissioning and staff training.

24-month warranty, with service support throughout the entire operating life of the equipment.

Call Get a quote